Goniophotometer Goniophotometer

Goniophotometer

GO-SPEX500 Goniospectroradiometer

GO-SPEX500 Goniospectroradiometer

Integrated Darkroom Design Accurate Measurement for Spatial Luminous Intensity & Color Distribution of Luminaires

Suitable for all kinds of indoor lamps, flood lamps, road lighting lamps and all kinds of light distribution performance test, total luminous flux, luminaire efficiency and electrical parameters (voltage, current, power, power factor) measurement.Test data can be saved as IESNA(*.ies), CIBSE(*.CIB), EULUMDAT(*.LDT), CIE(*.cie), CEN(*.cEN) and other formats, which can be directly used as the input data of international general lighting design software.

Features

  • Integrated Darkroom
    The system adopts a unique design scheme combining low stray obscural and extinction cylinder. Users do not have to build a special dark room for optical testing, and can achieve light distribution measurement of light sources and lamps under office conditions.
  • Mutual Data Correction
    The combined design of spectroradiometer and special precision photometer match and correct the spectral data during photometric measurement, so that the photometric measurement accuracy can be achieved.
  • Comprehensive Testing Capabilities
    The system integrates the functions of spatial luminous intensity distribution curve, total luminous flux and spatial color distribution (average color and spatial color non-uniformity), truly realizing the comprehensive test of the spatial characteristics of luminaires.
  • Highly Integrated System with Easy Operation
    The test system is highly integrated and easy to use, which integrates two rotation axes, AC-DC power supply, measuring unit and measuring and control software.

Technical Specifications

ModelGO-SPEX500
Automatic Luminaire Rotation Range0°–+360°; horizontal (C) axis rotation range: −180°–+180°
Two-Axis Angular AccuracyBetter than 0.1° on both axes
Maximum Test Sample SizeØ1000 mm (maximum emitting surface Ø600 mm), 400 mm thick
Maximum Turntable Load50kg
Maximum Output Torque of Horizontal Rotation Axis110Nm
Relative Spectral Responsivity Matching Accuracy of the DetectorClass A (Class L available upon request)
Photometric Measurement Range0.0001 lx–200 klx, autoranging
Photometric Linearity0.20%
Test SpeedThree selectable speeds: fast, medium, and slow
High-accuracy, high-speed spectroradiometer for precise measurement of the spatial chromaticity distribution, mean chromaticity characteristics, and spatial chromaticity non-uniformity of light sources or luminaires