START-1000 Start/run up Time Test System
High Sampling according to International Standard
Start-1000 can be used to record the start rise time and waveform of the light source in real time, and according to the design requirements of the EU directive 1194/2012, Energy Star and the international standard IEC60969, etc., it is specially used for LED lights, lamps and energy-saving lamps. And it can also be used to measure the photometry parameters of stable light sources.
Features
- 1. It integrates high precision and fast storage of photometric measurement, synchronous triggering of voltage zero crossing and touch screen display, and automatically obtains the start/rise time of light source through data analysis.
- 2. Precision photometric detector: CIE CLASS A, luminous flux measurement range: 0.1 lm~200 klm (related to the size of the supporting integrating sphere).
- 3. Trigger terminal voltage output stability: ≤0.2%, trigger terminal voltage total distortion THD: ≤0.5%.
Technical Specifications
| Model | START-1000 |
| Illuminance Measurement Range | 0.1 lx–100,000 lx, four measurement ranges |
| Illuminance Measurement Accuracy | Class 1 (±4%) |
| Sampling Rate | Selectable: 1 kS/s, 10 kS/s, or 100 kS/s |
| Sampling Duration | Configurable: 0.1–2000 s (1 kS/s), 0.1–200 s (10 kS/s), or 0.1–20 s (100 kS/s) |
| Instrument Dimensions | 665 mm (L) × 470 mm (W) × 198 mm (H) |
| Instrument Power Consumption | 115 W (with a 100 W incandescent lamp operated) |
| Instrument Weight | 20kg |